[1]张佳琪 池程伟 刘吉义 张树龙.心房颤动导管消融的新利器:脉冲电场消融[J].心血管病学进展,2022,(3):207-210.[doi:10.1016/j.tcm.2021.07.006. Epub ahead of print]
 ZHANG Jiaqi,CHI Chengwei,LIU Jiyi,et al.A Promising New Ablation Modality for Treatment of Atrial Fibrillation: Pulsed Field Ablation[J].Advances in Cardiovascular Diseases,2022,(3):207-210.[doi:10.1016/j.tcm.2021.07.006. Epub ahead of print]
点击复制

心房颤动导管消融的新利器:脉冲电场消融()
分享到:

《心血管病学进展》[ISSN:51-1187/R/CN:1004-3934]

卷:
期数:
2022年3期
页码:
207-210
栏目:
综述
出版日期:
2022-03-25

文章信息/Info

Title:
A Promising New Ablation Modality for Treatment of Atrial Fibrillation: Pulsed Field Ablation
文章编号:
202109015
作者:
张佳琪12 池程伟2 刘吉义2 张树龙2
(1.大连医科大学,辽宁 大连 116000;2.大连大学附属中山医院心内科,辽宁 大连 116001)
Author(s):
ZHANG Jiaqi12 CHI Chengwei2 LIU Jiyi2 ZHANG Shulong2
(1. Dalian Medical University,Dalian 116000,Liaoning,China; 2.Department of Cardiology,Affiliated Zhongshan Hospital of Dalian University,Dalian 116001,Liaoning,China)
关键词:
A Promising New Ablation Modality for Treatment of Atrial Fibrillation: Pulsed Field Ablation
Keywords:
Atrial fibrillationCatheter ablationPulsed field ablation
DOI:
10.1016/j.tcm.2021.07.006. Epub ahead of print
Abstract:
Radiofrequency ablation and cryoablation are the two main energy sources for catheter ablation of atrial fibrillation. As a new ablation energy for the treatment of arrhythmia,pulsed electric field forms nano pores on the cell membrane,resulting in cell apoptosis and irreversible electroporation. It has the characteristics of non thermal,transient and preferential selectivity of myocardial tissue,making atrial fibrillation catheter ablation simpler,safer and more effective,which may bring revolutionary changes to atrial fibrillation ablation

参考文献/References:

[1]Mansour M,Heist EK,Agarwal R,et al. Stroke and cardiovascular events after ablation or antiarrhythmic drugs for treatment of patients with atrial fibrillation[J]. Am J Cardiol,2018,121(10):1192-1199.
[2]Muthalaly RG,John RM,Schaeffer B,et al. Temporal trends in safety and complication rates of catheter ablation for atrial fibrillation[J]. J Cardiovasc Electrophysiol,2018,29(6):854-860.
[3]Bradley CJ,Haines DE. Pulsed field ablation for pulmonary vein isolation in the treatment of atrial fibrillation[J]. J Cardiovasc Electrophysiol,2020,31(8):2136-2147.
[4]Ramirez FD,Reddy VY,Viswanathan R,et al. Emerging technologies for pulmonary vein isolation[J]. Circ Res,2020,127(1):170-183.
[5]Rubinsky B,Onik G,Mikus P. Irreversible electroporation:a new ablation modality—Clinical implications[J]. Technol Cancer Res Treat,2007,6(1):37-48.
[6]Sugrue A,Vaidya V,Witt C,et al. Irreversible electroporation for catheter-based cardiac ablation:a systematic review of the preclinical experience[J]. J Interv Card Electrophysiol,2019,55(3):251-265.
[7]包阳扬,吴立群. 心脏脉冲电场消融进展[J]. 中华心律失常学杂志,2019,(6):498-503.
[8]Lavee J,Onik G,Mikus P,et al. A novel nonthermal energy source for surgical epicardial atrial ablation:irreversible electroporation[J]. Heart Surg Forum,2007,10(2):E162-E167.
[9]Reddy VY,Koruth J,Jais P,et al. Ablation of atrial fibrillation with pulsed?electric fields:an ultra-rapid,tissue-selective modality for cardiac ablation[J]. JACC Clin Electrophysiol,2018,4(8):987-995.
[10]Hong J,Stewart MT,Cheek DS,et al. Cardiac ablation via electroporation[J]. Annu Int Conf IEEE Eng Med Biol Soc,2009,2009:3381-3384.
[11]Stewart MT,Haines DE,Verma A,et al. Intracardiac pulsed field ablation:proof of feasibility in a chronic porcine model[J]. Heart Rhythm,2019,16(5):754-764.
[12]Squara F,Latcu DG,Massaad Y,et al. Contact force and force-time integral in atrial radiofrequency ablation predict transmurality of lesions[J]. Europace,2014,16(5):660-667.
[13]Leshem E,Zilberman I,Tschabrunn CM,et al. High-power and short-duration ablation for pulmonary vein isolation:biophysical?characterization[J]. JACC Clin Electrophysiol,2018,4(4):467-479.
[14]di Biase L,Diaz JC,Zhang XD,et al. Pulsed field catheter ablation in atrial fibrillation[J]. Trends Cardiovasc Med,2021 Jul 28:S1050-1738(21)00083-9. DOI:10.1016/j.tcm.2021.07.006. Epub ahead of print.
[15]Singh SM,d’Avila A,Singh SK,et al. Clinical outcomes after repair of left atrial esophageal fistulas occurring after atrial fibrillation ablation procedures[J]. Heart Rhythm,2013,10(11):1591-1597.
[16]Reddy VY,Neuzil P,Koruth JS,et al. Pulsed field ablation for pulmonary vein isolation in atrial fibrillation[J]. J Am Coll Cardiol,2019,74(3):315-326.
[17]Li W,Fan Q,Ji Z,et al. The effects of irreversible electroporation(IRE) on nerves[J]. PLoS One,2011,6(4):e18831.
[18]Koruth JS,Kuroki K,Kawamura I,et al. Focal pulsed field ablation for pulmonary vein isolation and linear atrial lesions:a preclinical assessment of safety and durability[J]. Circ Arrhythm Electrophysiol,2020,13(6):e008716.
[19]van Driel VJ,Neven K,van Wessel H,et al. Low vulnerability of the right phrenic nerve to electroporation ablation[J]. Heart Rhythm,2015,12(8):1838-1844.
[20]黄从新,张澍,黄德嘉,等. 心房颤动:目前的认识和治疗建议(2018)[J]. 中华心律失常学杂志,2018,(4):279-342.
[21]van Driel VJ,Neven KG,van Wessel H,et al. Pulmonary vein stenosis after catheter ablation:electroporation versus radiofrequency[J]. Circ Arrhythm Electrophysiol,2014,7(4):734-738.
[22]Reddy VY,Anic A,Koruth J,et al. Pulsed field ablation in patients with persistent atrial fibrillation[J]. J Am Coll Cardiol,2020,76(9):1068-1080.
[23]Reddy VY,Anter E,Rackauskas G,et al. Lattice-tip focal ablation catheter that toggles between radiofrequency and pulsed field energy to treat atrial fibrillation:a first-in-human trial[J]. Circ Arrhythm Electrophysiol,2020,13(6):e008718.
[24]Kuroki K,Whang W,Eggert C,et al. Ostial dimensional changes after pulmonary vein isolation:pulsed field ablation vs radiofrequency ablation[J]. Heart Rhythm,2020,17(9):1528-1535.
[25]Haines DE,Stewart MT,Dahlberg S,et al. Microembolism and catheter ablation I:a comparison of irrigated radiofrequency and multielectrode-phased radiofrequency catheter ablation of pulmonary vein ostia[J]. Circ Arrhythm Electrophysiol,2013,6(1):16-22.
[26]Reddy VY,Dukkipati SR,Neuzil P,et al. Pulsed field ablation of paroxysmal atrial fibrillation:1-year outcomes of IMPULSE,PEFCAT,and PEFCATⅡ[J]. JACC Clin Electrophysiol,2021,7(5):614-627.
[27]Koruth JS,Kuroki K,Iwasawa J,et al. Endocardial ventricular pulsed field ablation:a proof-of-concept preclinical evaluation[J]. Europace,2020,22(3):434-439.
[28]Kawamura I,Neuzil P,Shivamurthy P,et al. Does pulsed field ablation regress over time? A quantitative temporal analysis of pulmonary vein isolation[J]. Heart Rhythm,2021,18(6):878-884.
[29]Yavin H,Brem E,Zilberman I,et al. Circular multielectrode pulsed field ablation catheter lasso pulsed field ablation:lesion characteristics,durability,and effect on neighboring structures[J]. Circ Arrhythm Electrophysiol,2021,14(2):e009229.
[30]Xie F,Zemlin CW. Effect of twisted fiber anisotropy in cardiac tissue on ablation with pulsed electric fields[J]. PLoS One,2016,11(4):e0152262.

更新日期/Last Update: 2022-04-20