[1]伍星 郎明健 刘波 冯楠 陈英杰.无创心输出量监测仪ICON在CCU中的应用进展[J].心血管病学进展,2025,(12):1067.[doi:10.16806/j.cnki.issn.1004-3934.2025.12.003]
 WU Xing,LANG Ming jian,LIU Bo,et al.Application of Non-invasive Cardiac Output Monitoring in Coronary Care Unit[J].Advances in Cardiovascular Diseases,2025,(12):1067.[doi:10.16806/j.cnki.issn.1004-3934.2025.12.003]
点击复制

无创心输出量监测仪ICON在CCU中的应用进展()

《心血管病学进展》[ISSN:51-1187/R/CN:1004-3934]

卷:
期数:
2025年12期
页码:
1067
栏目:
综述
出版日期:
2025-12-25

文章信息/Info

Title:
Application of Non-invasive Cardiac Output Monitoring in Coronary Care Unit
作者:
伍星 郎明健 刘波 冯楠 陈英杰
(成都市第五人民医院(成都中医药大学附属第五人民医院/第二临床医学院)
Author(s):
WU XingLANG Ming jianLIU BoFENG NanCHEN Yingjie
(Geriatric Diseases Institute of Chengdu/Cancer Prevention and Treatment Institute of Chengdu,Department of Cardiovascular,Chengdu Fifth People’s Hospital(The Second Clinical Medical College,Affliated Fifth People’s Hospital of Chengdu University of Traditional Chinese Medicine),Chengdu 611137,Sichuan,China)
关键词:
无创监测血流动力学冠心病监护病房生物阻抗
Keywords:
Non-invasive monitoring Hemodynamics Coronary care unit Bioimpedance
DOI:
10.16806/j.cnki.issn.1004-3934.2025.12.003
摘要:
随着重症医学的进步,无创血流动力学监测在CCU日益普遍。无创心输出量监测仪(ICON)通过生物阻抗无创监测,可实现对心输出量、每搏输出量和周围血管阻力等血流动力学参数的实时测量,并给予心力衰竭或休克等重症患者定制化治疗。现回顾无创心输出量监测仪的技术原理、临床优势、临床证据与发展方向。
Abstract:
With the advancement of intensive care medicine,non-invasive hemodynamic monitoring has become increasingly common in the coronary care unit (CCU). The non-invasive cardiac output monitor(ICON?),utilizing bioimpedance-based non-invasive monitoring,allows for real-time measurement of hemodynamic parameters such as cardiac output,stroke volume,and systemic vascular resistance. It provides tailored treatment for critically ill patients,such as those with heart failure or shock. This review outlines the technical principles,clinical advantages,clinical evidence,and future directions of the non-invasive cardiac output monitoring device

参考文献/References:

[1] Diaz-Arocutipa C,Moreno G,Gil DG,et al. Effect of pulmonary artery catheterization in patients with non-ischemic cardiogenic shock:a nationwide analysis[J]. Shock,2024,62(2):186-192.

[2] Meng QL,Sun Y,He H,et al. Non-invasive thoracic electrical bioimpedance technique-derived hemodynamic reference ranges in Chinese Han adults[J]. Chin Med J,2021,134(20):2515-2517.

[3] Yang Y,Qian Q,Yang XY,et al. Measurement of non-invasive cardiac output during cycling exercise in ischemic stroke inpatients:a pilot study [J]. Technol Health Care,2023,32(1):215-228.

[4] Sel K,Asgar SAG,Osman D,et al.Wearable bioimpedance sensor characterization for blood flow monitoring[C]//2023 IEEE biomedical circuits and systems conference (BioCAS).IEEE,2023:1-5.doi:10.1109/biocas58349.2023.10388901.

[5] Mahajan S,Gu J,Lu Y,et al. Hemodynamic phenotypes of hypertension based on cardiac output and systemic vascular resistance[J]. Am J Med,2020,133(4):e127-e139.

[6] Kadafi KT,Latief A,Pudjiadi AH. Determining pediatric fluid responsiveness by stroke volume variation analysis using ICON? electrical cardiometry and ultrasonic cardiac output monitor :A cross-sectional study[J]. Int J Crit Illn Inj Sci,2020,10(3):123-128.

[7] Galas A,Krzesiński P,Gielerak G. Thoracic fluid content as a useful diagnostic marker of resting dyspnoea in patients hospitalised due to acute heart failure[J]. Pediatr Med Rodz,2024,20(1):52-57.

[8] Zakarias D,Marics G,Kovacs K,et al. Clinical application of the electric cardiometry based non-invasive ICON(R) hemodynamic monitor[J]. Orv Hetil,2018,159(44):1775-1781.

[9] Douglas I,Elwan M,Najarro M,et al. Dynamic monitoring tools for patients admitted to the emergency department with circulatory failure:narrative review with panel-based recommendations[J]. Eur J Emerg Med,2024,31(2):98-107.

[10] Shacham Y,Stern T,Stern T,et al. Using continuous electronic urine output monitoring for the management of acute cardio-renal syndrome in patients with acute decompensated heart failure[J]. Eur Heart J Acute Cardiovasc Care,2024,13(suppl 1):zuae036. 023.

[11] Galas A,Krzesiński P,Banak M,et al. Thoracic fluid content as an indicator of high Intravenous diuretic requirements in hospitalized patients with decompensated heart failure[J]. J Clin Med,2024,13(8):5625.

[12] Cavusoglu Y,Altay H,Nalbantgil S,et al. Pre-discharge and post-discharge management and treatment optimization in acute heart failure[J]. Turk Kardiyol Dernegi Arsiv,2022,50(5):378-394.

[13] Algoet M,Janssens S,Himmelreich U,et al. Myocardial Ischemia-Reperfusion Injury and the Influence of Inflammation[J]. Trends Cardiovasc Med,2023,33(6):357-366.

[14] St?pniak P,Cacko A,Ko?odzińska A,et al. Non-invasive methods of cardiac output measurement and their importance in everyday clinical practice:the current state of knowledge[J]. Folia Cardiol,2021,16(4):237-241.

[15] Rali A,Buechler T,van Gotten B,et al. Non-invasive cardiac output monitoring in cardiogenic shock:the NICOM study[J]. J Cardiac Fail,2019,26(2):160-165.

[16] Rao S,Lalitha A,Reddy M,et al. Electrocardiometry for hemodynamic categorization and assessment of fluid responsiveness in pediatric septic shock:a pilot observational study[J]. Indian J Crit Care Med,2021,25(2):185-192.

[17] Karim HMR. Cardio circulatory and respiratory monitoring of mechanically ventilated critically ill patients[J]. Anaesth Pain Intensive Care,2018,22(suppl 1):S142-S149.

[18] Vankar S,Sharma A,Dwivedi S,et al. Invasive assessment of fluid therapy in hypotensive patients of postinferior wall myocardial infarction complicated by right ventricular infarction[J]. Heart India,2021,9(2):95-101.

[19] Majella J,Chhabra S. Right heart catheterization-revisited[J]. Indian J Cardiovasc Dis Women,2023,9(1):28-34.

[20] Wu Y,Tian P,Liang L,et al. Afterload-related cardiac performance is a powerful hemodynamic predictor of mortality in patients with chronic heart failure[J]. Therapeutic Advances in Chronic Disease,2023,14:20406223231171554.

[21] Mukai A,Suehiro K,Kimura A,et al. Effect of systemic vascular resistance on the reliability of noninvasive hemodynamic monitoring in cardiac surgery[J]. J Cardiothorac Vasc Anesth,2020,35(6):1782-1791.

[22] Soaida S,Hanna M,Mahmoud A,et al. Electrical velocimetry (ICON cardiometry) assessment of hemodynamic changes associated with different inflation pressures during pediatric thoracoscopic surgery:A pilot study[J]. EJCTA,2021,15(1):3-9.

[23] Lorenzen U,Grünewald M. Targeted hemodynamic monitoring in the operating theatre:what for and by what means?[J]. Anasthesiol Intensivmed Notfallmed Schmerzther,2022,57(4):246-262.

[24] Capiga D,Czy?ewski L. Non-invasive assessment of haemodynamic parameters in an Emergency Department[J]. Disaster Emerg Med J,2020,5(3):142-149.

[25] Eyeington C,Lloyd-Donald P,Chan M,et al. Non-invasive continuous haemodynamic monitoring and response to intervention in haemodynamically unstable patients during rapid response team review[J]. Resuscitation,2019,143:124-133.

[26] Patel K,Reddy R,Sau A,et al. Obesity as a risk factor for cardiac arrhythmias[J]. BMJ Med,2022,1(1):e000308.

[27] González-Fajardo J,Ansuátegui M,Romero C,et al. Atrial fibrillation and surgical patients with peripheral arterial disease[J]. Ann Vasc Surg,2020,67:411-416.

[28] Szekely Y,Brahmbhatt D,Scolari F,et al. Non-invasive assessment of right ventricular function and pulmonary pressures in cardiogenic shock remains challenging:Don’t pack away the PAC just yet[J]. Eur Heart J,2022,43(Suppl 2):ehac544. 1093.

相似文献/References:

[1]张国振 何庆.维生素 C对心脏骤停动物模型复苏后心功能的影响[J].心血管病学进展,2020,(7):770.[doi:10.16806/j.cnki.issn.1004-3934.2020.07.023]
 ZHANG Guozhen,HE Qing.Effect of Vitamin C on Cardiac Function after Resuscitation in Animal Models of Cardiac A rrest[J].Advances in Cardiovascular Diseases,2020,(12):770.[doi:10.16806/j.cnki.issn.1004-3934.2020.07.023]
[2]常羽茜 李昱熙 刘旭 刘志浩 张岩.肾动脉狭窄介入治疗中的血流动力学评估进展[J].心血管病学进展,2024,(3):196.[doi:10.16806/j.cnki.issn.1004-3934.2024.03.002]
 CHANG Yuxi,LI Yuxi,LIU Xu,et al.Hemodynamic Evaluation in Interventional Treatment of Renal Artery Stenosis[J].Advances in Cardiovascular Diseases,2024,(12):196.[doi:10.16806/j.cnki.issn.1004-3934.2024.03.002]

更新日期/Last Update: 2026-04-14