[1]赵震 孙雪荣 乔宇 郭雨龙 郭金锐 刘可 刘晨 刘帆 郭涛 牛国栋.心房颤动高功率短时程消融策略的研究进展[J].心血管病学进展,2021,(10):878.[doi:10.16806/j.cnki.issn.1004-3934.2021.10.004]
 ZHAO Zhen,SUN Xuerong,QIAO Yu,et al.High-power Short-duration Ablation Strategy for Atrial Fibrillation[J].Advances in Cardiovascular Diseases,2021,(10):878.[doi:10.16806/j.cnki.issn.1004-3934.2021.10.004]
点击复制

心房颤动高功率短时程消融策略的研究进展()
分享到:

《心血管病学进展》[ISSN:51-1187/R/CN:1004-3934]

卷:
期数:
2021年10期
页码:
878
栏目:
综述
出版日期:
2021-10-25

文章信息/Info

Title:
High-power Short-duration Ablation Strategy for Atrial Fibrillation
作者:
赵震12 孙雪荣 3 乔宇 1 郭雨龙 1 郭金锐 1 刘可 1 刘晨 1 刘帆 1 郭涛 1 牛国栋 3
(1.昆明医科大学附属心血管病医院 云南省阜外心血管病医院心律失常中心,云南 昆明 650102;2.昆明医科大学研究生院,云南 昆明 650000;3.中国医学科学院 北京协和医学院 国家心血管病中心 阜外医院 心律失常中心,北京 100037)
Author(s):
ZHAO Zhen12SUN Xuerong3QIAO Yu1GUO Yulong1GUO Jinrui1LIU Ke1LIU Chen1LIU Fan1GUO Tao1NIU Guodong3?/html>
(1. Arrhythmia Center ,Fuwai Yunnan Cardiovascular Hospital,The Affiliated Cardiovascular Hospital of Kunming Medical University ,Kunming 650102,Yunnan,China; 2. Graduate School of Kunming Medical University,Kunming 650000,Yunnan ,China; 3.Arrhythmia Center,Fuwai Hospital,National Center for Cardiovascular Diseases,Chinese Academy of Medical Sciences,Peking Union Medical College,Beijing 100037,China)
关键词:
高功率短时程射频消融心房颤动消融参数
Keywords:
High-power short-durationRadiofrequency ablationAtrial fibrillationAbaltion parameters
DOI:
10.16806/j.cnki.issn.1004-3934.2021.10.004
摘要:
肺静脉隔离是心房颤动导管消融的基础,目前主流术式是通过逐点射频消融策略实现肺静脉隔离,但由于传统消融模式只能实现40 W以下的安全输出,各点均需较长时间才能实现透壁毁损,不利于推广。近年来,随着消融设备的进步,可实现高功率(45~90 W)输出,大幅缩短手术时间,即高功率短时程消融,可以避免导管长时间操作及放电带来的一系列问题,在一定程度上可提高手术成功率。现从基础和临床研究两方面对HPSD消融的现状进行总结,并就其优势及局限性进行综述。
Abstract:
Pulmonary vein isolation (PVI) is the cornerstone of atrial fibrillation catheter ablation,the current mainstream procedure is to achieve PVI through a point-by-point radiofrequency ablation strategy,but the traditional ablation mode can only achieve the safe output of below 40 W,it takes a long time for each point to accomplish transmural destruction,which is not conducive to promotion. Recently,with the improvement of ablation equipment,high power (45~90 W) output can be realized,and the operation time can be greatly shortened,that is,high-power short-duration (HPSD) ablation,which can avoid a series of problems caused by prolonged catheter operation and discharge,and improves the success rate of the procedure. This article summarizes the current research on HPSD ablation from basic and clinical studies and reviews its advantages and limitations.

参考文献/References:

[1].Hindricks G, Potpara T, Dagres N, et al. 2020 ESC Guidelines for the diagnosis and management of atrial fibrillation developed in collaboration with the European Association of Cardio-Thoracic Surgery (EACTS)[J]. Eur Heart J, 2020.
[2].Andrade J G, Monir G, Pollak S J, et al. Pulmonary vein isolation using "contact force" ablation: the effect on dormant conduction and long-term freedom from recurrent atrial fibrillation--a prospective study[J]. Heart Rhythm, 2014, 11(11): 1919-24.
[3].Buist TJ, Zipes DP, Elvan A. Atrial fibrillation ablation strategies and technologies: past, present, and future[J]. Clin Res Cardiol,2021,110(6):775-788.
[4].Winkle RA. High-power short-duration RF ablation for atrial fibrillation:a review[J]. J Cardiovasc Electrophysiol,2020 Dec 31. doi: 10.1111/jce.14863.
[5].Yavin HD, Leshem E, Shapira-Daniels A, et al. Impact of high-power short-duration radiofrequency ablation on long-term lesion durability for atrial fibrillation ablation[J]. JACC Clin Electrophysiol,2020,6(8):973-985.
[6].Bhaskaran A, Chik W, Pouliopoulos J, et al. Five seconds of 50-60 W radio frequency atrial ablations were transmural and safe: an in vitro mechanistic assessment and force-controlled in vivo validation[J]. Europace, 2017, 19(5): 874-880.
[7].Leshem E, Zilberman I, Tschabrunn CM, et al. High-power and short-duration ablation for pulmonary vein isolation:biophysical characterization[J]. JACC Clin Electrophysiol,2018,4(4):467-479.
[8].Takigawa M, Kitamura T, Martin CA, et al. Temperature- and flow-controlled ablation/very-high-power short-duration ablation vs conventional power-controlled ablation:Comparison of focal and linear lesion characteristics[J]. Heart rhythm,?2021,18(4):553-561.
[9].Chinitz JS, Kapur S, Barbhaiya C, et al. Sites with small impedance decrease during catheter ablation for atrial fibrillation are associated with recovery of pulmonary vein conduction[J]. J Cardiovasc Electrophysiol,2016,27(12):1390-1398.
[10].[10] Kanamori N, Kato T, Sakagami S, et al. Optimal lesion size index to prevent con- duction gap during pulmonary vein isolation[J]. J Cardiovasc Electrophysiol,2018,29 (12):1616-1623.
[11].[11] Pambrun T, Durand C, Constantin M, et al. High-Power (40-50 W) Radiofrequency Ablation Guided by Unipolar Signal Modification for Pulmonary Vein Isolation: Experimental Findings and Clinical Results[J]. Circ Arrhythm Electrophysiol, 2019, 12(6): e007304.
[12].[12] Taghji P, El Haddad M, Phlips T, et al. Evaluation of a Strategy Aiming to Enclose the Pulmonary Veins With Contiguous and Optimized Radiofrequency Lesions in Paroxysmal Atrial Fibrillation: A Pilot Study[J]. JACC. Clinical electrophysiology, 2018, 4(1).
[13].[13] Bourier F, Vlachos K, Frontera A, et al. In silico analysis of the relation between conventional and high-power short-duration RF ablation settings and resulting lesion metrics[J]. J Cardiovasc Electrophysiol,2020,31(6):1332-1339.
[14].[14] Okamatsu H, Koyama J, Sakai Y, et al. High-power application is associated with shorter procedure time and higher rate of first-pass pulmonary vein isolation in ablation index-guided atrial fibrillation ablation[J]. J Cardiovasc Electrophysiol, 2019, 30(12): 2751-2758.
[15].[15] Berte B, Hilfiker G, Russi I, et al. Pulmonary vein isolation using a higher power shorter duration CLOSE protocol with a surround flow ablation catheter[J]. J Cardiovasc Electrophysiol,2019,30(11):2199-2204.
[16].[16] Vassallo F, Cunha C, Serpa E, et al. Comparison of high-power short-duration (HPSD) ablation of atrial fibrillation using a contact force-sensing catheter and conventional technique: Initial results[J]. J Cardiovasc Electrophysiol, 2019, 30(10): 1877-1883.
[17].[17] Bunch TJ, May HT, Bair TL, et al. Long-term outcomes after low power,slower movement versus high power,faster movement irrigated-tip catheter ablation for atrial fibrillation[J]. Heart Rhythm,2020,17(2):184-189.
[18].[18] Kottmaier M, Popa M, Bourier F, et al. Safety and outcome of very high-power short-duration ablation using 70 W for pulmonary vein isolation in patients with paroxysmal atrial fibrillation[J]. Europace,2020,22(3):388-393.
[19].[19] Ejima K, Higuchi S, Yazaki K, et al. Comparison of high-power and conventional-power radiofrequency energy deliveries in pulmonary vein isolation using unipolar signal modification as a local endpoint[J]. J Cardiovasc Electrophysiol, 2020, 31(7): 1702-1708.
[20].[20] Shin DG, Ahn J, Han SJ, et al. Efficacy of high-power and short-duration ablation in patients with atrial fibrillation:a prospective randomized controlled trial[J]. Europace,2020,22(10):1495-1501.
[21].[21] 孙国建, 王浩, 陈宇宁, 等。损伤指数指导下心房颤动高功率消融临床研究[J]. 心电与循环,2020,39(2):164-167.
[22].[22] Ravi V, Poudyal A, Abid QU, et al. High-power short duration vs. conventional radiofrequency ablation of atrial fibrillation:a systematic review and meta-analysis[J]. Europace,2021,23(5):710-721.
[23].[23] Winkle RA, Mead RH, Engel G, et al. High-power,short-duration atrial fibrillation ablations using contact force sensing catheters:outcomes and predictors of success including posterior wall isolation[J]. Heart Rhythm,2020,17(8):1223-1231.
[24].[24] Winkle RA, Mohanty S, Patrawala RA, et al. Low complication rates using high power (45-50 W) for short duration for atrial fibrillation ablations[J]. Heart Rhythm,2019,16(2):165-169.
[25].[25] De Pooter J, Strisciuglio T, El Haddad M, et al. Pulmonary Vein Reconnection No Longer Occurs in the Majority of Patients After a Single Pulmonary Vein Isolation Procedure[J]. JACC Clin Electrophysiol, 2019, 5(3): 295-305.
[26].[26] Chen S, Schmidt B, Bordignon S, et al. Ablation index-guided 50 W ablation for pulmonary vein isolation in patients with atrial fibrillation:procedural data,lesion analysis,and initial results from the FAFA AI High Power Study[J]. J Cardiovasc Electrophysiol,2019,30(12):2724-2731.

相似文献/References:

[1]简军 殷跃辉.APPLE评分与心房颤动[J].心血管病学进展,2020,(6):616.[doi:10.16806/j.cnki.issn.1004-3934.2020.06.014]
 JIAN Jun,YIN Yuehui.The APPLE Score and Atrial Fibrillation[J].Advances in Cardiovascular Diseases,2020,(10):616.[doi:10.16806/j.cnki.issn.1004-3934.2020.06.014]
[2]范建华 刘庆军.高功率短时程射频消融治疗心房颤动的研究进展[J].心血管病学进展,2020,(8):806.[doi:10.16806/j.cnki.issn.1004-3934.2020.08.006]
 FAN JIanhuaLIU Qingjun.High Power Short Duration Radiofrequency Ablation for Atrial Fibrillation[J].Advances in Cardiovascular Diseases,2020,(10):806.[doi:10.16806/j.cnki.issn.1004-3934.2020.08.006]
[3]颜如玉 赵海玉 张建武 彭健.心房颤动高功率短时程消融的临床应用进展[J].心血管病学进展,2021,(1):39.[doi:10.16806/j.cnki.issn.1004-3934.2021.01.000]
 YAN Ruyu,ZHAO Haiyu,ZHANG Jianwu,et al.Clinical Application of High-power and Short-term Ablation for Atrial Fibrillation[J].Advances in Cardiovascular Diseases,2021,(10):39.[doi:10.16806/j.cnki.issn.1004-3934.2021.01.000]
[4]洪璐 曹明强 周亚峰.2016年ASE/EACVI指南评估的左室舒张功能对阵发性心房颤动术后复发的预测价值[J].心血管病学进展,2021,(5):464.[doi:10.16806/j.cnki.issn.1004-3934.2021.05.019]
 HONG Lu,CAO Mingqiang,ZHOU Yafeng.Predictive Value of Left Ventricular Diastolic Function Assessed by 2016 ASE/EACVI Guidelines for Postoperative Recurrence of Paroxysmal Atrial Fibrillation[J].Advances in Cardiovascular Diseases,2021,(10):464.[doi:10.16806/j.cnki.issn.1004-3934.2021.05.019]
[5]徐尧 蔡衡 李洪仕.射频消融与药物治疗对心房颤动合并心力衰竭患者的疗效差异比较[J].心血管病学进展,2022,(3):274.[doi:10.16806/j.cnki.issn.1004-3934.2022.03.000]
[6]李宸 章海燕 徐少华 许海南 张祖宏 龙明智.消融指数指导心房颤动射频消融的有效性和安全性的荟萃分析[J].心血管病学进展,2022,(2):171.[doi:10.16806/j.cnki.issn.1004-3934.2022.02.019]
 LI Chen,ZHANG Haiyan,XU Shaohua,et al.Efficacy and Safety of Radiofrequency Ablation of Atrial Fibrillation Guided by?blation Index: A Meta-Analysis[J].Advances in Cardiovascular Diseases,2022,(10):171.[doi:10.16806/j.cnki.issn.1004-3934.2022.02.019]
[7]柯嘉伟 黄松群 黄新苗 马丽萍.左心房心房扑动射频消融治疗进展[J].心血管病学进展,2023,(5):425.[doi:10.16806/j.cnki.issn.1004-3934.2023.05.010]
 KE Jiawei,HUANG Songqun,HUANG Xinmiao,et al.Advances in Radiofrequency Catheter Ablation of Left Atrial Flutter[J].Advances in Cardiovascular Diseases,2023,(10):425.[doi:10.16806/j.cnki.issn.1004-3934.2023.05.010]

更新日期/Last Update: 2021-12-02