[1]马成杰 沈健 吴弘.心脏植入式电子设备电极导线相关三尖瓣反流的研究进展[J].心血管病学进展,2025,(8):673.[doi:10.16806/j.cnki.issn.1004-3934.2025.08.001]
 MA Chengjie,SHENG Jian,WU Hong.Advances in Tricuspid Regurgitation Associated?ith Cardiac Implantable Electronic Device Electrode Leads[J].Advances in Cardiovascular Diseases,2025,(8):673.[doi:10.16806/j.cnki.issn.1004-3934.2025.08.001]
点击复制

心脏植入式电子设备电极导线相关三尖瓣反流的研究进展()

《心血管病学进展》[ISSN:51-1187/R/CN:1004-3934]

卷:
期数:
2025年8期
页码:
673
栏目:
综述
出版日期:
2025-08-25

文章信息/Info

Title:
Advances in Tricuspid Regurgitation Associated?ith Cardiac Implantable Electronic Device Electrode Leads
作者:
马成杰 沈健 吴弘
(海军军医大学第一附属医院心血管内科,上海 200433)
Author(s):
MA ChengjieSHENG JianWU Hong
?Department of CardiologyThe First Affiliated Hospital of Naval Medical UniversityShanghai 200433China)
关键词:
心脏植入式电子设备三尖瓣反流电极导线
Keywords:
Cardiac implantable electronic deviceTricuspid regurgitationElectrode lead
DOI:
10.16806/j.cnki.issn.1004-3934.2025.08.001
摘要:
心脏植入式电子设备(CIED)电极导线与三尖瓣瓣叶之间的相互作用可能是导致三尖瓣反流(TR)的主要原因,而TR又会影响患者心力衰竭的发病率和死亡率。研究发现,电极导线通过机械干扰、心室重塑及瓣环扩张等机制诱发或加重TR。目前,CIED植入后电极导线与TR进展之间的关系尚无定论。现综述CIED相关TR的流行病学特征、电极导线相关TR的发生机制和临床管理的研究进展,旨在阐明CIED对三尖瓣的影响及机制,减少CIED植入后电极导线对三尖瓣的影响,优化CIED治疗策略。
Abstract:
The interaction between cardiac implantable electronic device (CIED) leads and tricuspid valve leaflets may be a primary cause of tricuspid regurgitation (TR),which in turn affects the morbidity and mortality of heart failure in patients. Studies have shown that CIED leads induce or exacerbate TR through mechanisms such as mechanical interference,ventricular remodeling,and annular dilation. Currently,the relationship between CIED leads placement and TR progression remains inconclusive. This review summarizes recent advances in the epidemiological characteristics ,mechanisms,and clinical management of CIED-related TR. It aims to elucidate the impact and underlying mechanisms of CIEDs on the tricuspid valve,reduce lead-induced tricuspid valve dysfunction post-implantation,and optimize CIED therapeutic strategies

参考文献/References:

[1] Chodór-Rozwadowska KE,Sawicka M,Morawski S,et al. Lead-related tricuspid regurgitation and ventricle dysfunction:current management and future perspectives[J]. Adv Clin Exp Med,2023,32(9):1049-1061.

[2] Rao VN,Giczewska A,Chiswell K,et al. Long-term outcomes of phenoclusters in severe tricuspid regurgitation[J]. Eur Heart J,2023,44(21):1910-1923.

[3] 信满坤,张抒扬. 双腔永久起搏器置入术后长期并发症的研究进展[J]. 心肺血管病杂志,2019,38(10):1066-1070.

[4] 黄国勇,陈开红,宋伟,等. 心脏起搏器植入术后三尖瓣反流影响因素分析[J]. 中外医学研究,2020,18(17):57-59.

[5] Murphy SP,Lew J,Yucel E,et al. Cardiac implantable electronic device-induced tricuspid regurgitation:implications and management[J]. J Cardiovasc Electrophysiol,2024,35(5):1017-1025.

[6] 王世栋,王钊,朱浩杰,等. 埋藏式心律转复除颤器的除颤电极植入部位对三尖瓣反流的影响[J]. 中国循环杂志,2022,37(2):142-147.

[7] Al-Bawardy R,Krishnaswamy A,Bhargava M,et al. Tricuspid regurgitation in patients with pacemakers and implantable cardiac defibrillators:a comprehensive review[J]. Clin Cardiol,2013,36(5):249-54.

[8] Gelves-Meza J,Lang RM,Valderrama-Achury MD,et al. Tricuspid regurgitation related to cardiac implantable electronic devices:an integrative review[J]. J Am Soc Echocardiogr,2022,35(11):1107-1122.

[9] Klutstein M,Balkin J,Butnaru A,et al. Tricuspid incompetence following permanent pacemaker implantation[J]. Pacing Clin Electrophysiol,2009,32 suppl 1:S135-S137.

[10] Anvardeen K,Rao R,Hazra S,et al. Lead-specific features predisposing to the development of tricuspid regurgitation after endocardial lead implantation[J]. CJC Open,2019,1(6):316-323.

[11] Kim K,Murai R,Okada T,et al. Incidence,time course,and outcomes of worsening tricuspid regurgitation following transvenous cardiac implantable electronic device implantation[J]. Am J Cardiol,2024,232:8-17.

[12] Webster G,Margossian R,Alexander ME,et al. Impact of transvenous ventricular pacing leads on tricuspid regurgitation in pediatric and congenital heart disease patients[J]. J Interv Card Electrophysiol,2008,21(1):65-68.

[13] Addetia K,Maffessanti F,Mediratta A,et al. Impact of implantable transvenous device lead location on severity of tricuspid regurgitation[J]. J Am Soc Echocardiogr,2014,27(11):1164-1175.

[14] 钟蕾,李锐洁. 电极相关三尖瓣反流研究进展[J]. 心血管病学进展,2019,40(1):53-56.

[15] Mediratta A,Addetia K,Yamat M,et al. 3D echocardiographic location of implantable device leads and mechanism of associated tricuspid regurgitation[J]. JACC Cardiovasc Imaging,2014,7(4):337-347.

[16] Chang JD,Manning WJ,Ebrille E,et al. Tricuspid valve dysfunction following pacemaker or cardioverter-defibrillator implantation[J]. J Am Coll Cardiol,2017,69(18):2331-2341.

[17] 郭继鸿. 电极导线介导的三尖瓣反流[J]. 临床心电学杂志,2014,23(6):455-466.

[18] Lin G,Nishimura RA,Connolly HM,et al. Severe symptomatic tricuspid valve regurgitation due to permanent pacemaker or implantable cardioverter-defibrillator leads[J]. J Am Coll Cardiol,2005,45(10):1672-1675.

[19] Nakajima H,Seo Y,Ishizu T,et al. Features of lead-induced tricuspid regurgitation in patients with heart failure events after cardiac implantation of electronic devices— a three-dimensional echocardiographic study[J]. Circ J,2020,84(12):2302-2311.

[20] Iliescu ?,Voroneanu L,Covic AM,et al. Tricuspid regurgitation associated with implantable cardiac devices:a double-edged sword[J]. J Clin Med,2024,13(18):5543.

[21] 成艳,姚磊,高欢欢,等. 经胸实时三维超声心动图在诊断起搏导线相关性三尖瓣关闭不全中的应用[C]. 嘉兴:2019年浙江省医学会超声医学学术大会,2019.

[22] 林雪琪. 经胸超声心动图评价右心室电极导线植入后三尖瓣反流的发生率及影响因素[D]. 杭州:浙江大学,2021.

[23] 张文成. 永久起搏器右室导线植入位置与三尖瓣反流加重的机制及影响因素相关性研究[D]. 兰州:兰州大学,2021.

[24] Chodór-Rozwadowska K,Sawicka M,Morawski S,et al. Impact of lead position on tricuspid regurgitation,ventricular function,and heart failure exacerbation and mortality after cardiac implantable electronic device implantation. Preliminary results from the PACE-RVTR Registry[J]. Kardiol Pol,2024,82(1):53-62.

[25] Andreas M,Burri H,Praz F,et al. Tricuspid valve disease and cardiac implantable electronic devices[J]. Eur Heart J,2024,45(5):346-365.

[26] 曾春芳,李天发,刘先霞,等. 老年人永久起搏器术后电极导线脱位原因[J]. 实用医技杂志,2011,18(6):650-651.

[27] 苏群英. 经胸超声心动图评价起搏器植入术后三尖瓣反流发生率及影响因素的研究[D]. 南宁:广西医科大学,2019.

[28] Hahn RT,Wilkoff BL,Kodali S,et al. Managing implanted cardiac electronic devices in patients with severe tricuspid?regurgitation:JACC state-of-the-art review[J]. J Am Coll Cardiol,2024,83(20):2002-2014.

[29] 史成龙,张海青,苑洪涛,等. 心血管植入式电子器械与三尖瓣反流加重的影响因素[J]. 中华老年多器官疾病杂志,2019,18(3):180-184.

[30] 李超,戴研,李玉秋,等. 心脏起搏导线相关三尖瓣反流的危险因素分析[J]. 中华心律失常学杂志,2020,24(5):472-476.

[31] 郭继鸿,许原,李学斌. 起搏电极导线脱位的临床探讨[J]. 中国心脏起搏与心电生理杂志,2002,16(1):8-10.

[32] 鲁静朝,刘凡,崔炜,等. 起搏器电极导线脱位的临床因素分析及相应处理策略[J]. 临床荟萃,2006,21(23):1720-1721.

[33] 郭雨龙,付明鹏,刘晨,等. 无导线起搏与传统起搏对三尖瓣反流短期影响的对比研究[J]. 中国心血管杂志,2023,28(4):323-327.

[34] Heidenreich PA,Bozkurt B,Aguilar D,et al. 2022 AHA/ACC/HFSA Guideline for the management of heart failure:a report of the American College of Cardiology/American Heart Association Joint Committee on Clinical Practice Guidelines[J]. Circulation,2022,145(18):e895-e1032.

[35] Shanafelt C,Middour TG,Ibrahim R,et al. Outcomes of tricuspid regurgitation after lead extraction[J]. J Cardiovasc Electrophysiol,2024,35(5):929-938.

[36] 王伟,安朝,李宁,等. 行介入三尖瓣置换术治疗起搏器引起的重度三尖瓣关闭不全1例[J]. 中国介入心脏病学杂志,2021,29(2):116-118.

[37] 徐荣丰,丁建东,马根山. 经导管缘对缘修复术治疗三尖瓣反流的现状和挑战[J]. 中国医学前沿杂志(电子版),2024,16(1):72-78.

[38] Nickenig G,Lurz P,Sorajja P,et al. Percutaneous edge-to-edge repair for tricuspid regurgitation:3-year outcomes from the TRILUMINATE study[J]. JACC Cardiovasc Interv,2024,17(18):2113-2122.

相似文献/References:

[1]罗亮 汤宝鹏 周贤惠.三尖瓣反流与心房颤动的研究进展[J].心血管病学进展,2024,(8):681.[doi:10.16806/j.cnki.issn.1004-3934.202.08.003]
 LUO Liang,TANG Baopeng,ZHOU Xianhui.Tricuspid Regurgitation and Atrial Fibrillation[J].Advances in Cardiovascular Diseases,2024,(8):681.[doi:10.16806/j.cnki.issn.1004-3934.202.08.003]

更新日期/Last Update: 2025-11-11