[1]余超 韩月清 毕静婷 邢磊.支架术后即刻冠状动脉光学相干断层显像结果的临床影响[J].心血管病学进展,2024,(7):581.[doi:10.16806/j.cnki.issn.1004-3934.2024.07.002]
 Yu Chao,Han Yueqing,Bi Jingting,et al.The Clinical Influence of Poststent Optical Coherence Tomographic Findings of Coronary Artery[J].Advances in Cardiovascular Diseases,2024,(7):581.[doi:10.16806/j.cnki.issn.1004-3934.2024.07.002]
点击复制

支架术后即刻冠状动脉光学相干断层显像结果的临床影响()
分享到:

《心血管病学进展》[ISSN:51-1187/R/CN:1004-3934]

卷:
期数:
2024年7期
页码:
581
栏目:
综述
出版日期:
2024-07-25

文章信息/Info

Title:
The Clinical Influence of Poststent Optical Coherence Tomographic Findings of Coronary Artery
作者:
余超 韩月清 毕静婷 邢磊
(哈尔滨医科大学附属第二医院心内科 教育部心肌缺血重点实验室,黑龙江 哈尔滨150081)
Author(s):
Yu ChaoHan YueqingBi Jingting Xinglei
(Department of Cardiology, The Second Affiliated Hospital of Harbin Medical University The Key Laboratory of Myocardial Ischemia, Chinese Ministry of Education, Harbin 150081,Heilongjiang,China)
关键词:
支架术后即刻血管内影像学冠状动脉光学相干断层显像结果临床影响
Keywords:
Poststent Intravascular imaging Optical coherence tomographic finding of coronary artery Clinical Influence
DOI:
10.16806/j.cnki.issn.1004-3934.2024.07.002
摘要:
冠状动脉光学相干断层显像的分辨率达到10μm,它可为术者提供支架贴壁不良、组织脱垂、支架内血栓和支架边缘夹层等支架术后即刻结果,但其对临床预后的影响一直存在争议。现总结既往研究,并就支架术后即刻冠状动脉光学相干断层显像结果的研究进展及临床影响进行综述。
Abstract:
Although the distinguishability of Optical coherence tomography (OCT) has been reach 10μm which can provides detailed information such as stent malapposition,tissue prolapse, thrombus, and dissection, the clinical influence of poststent OCT findings has been controversial. This article aims at summarize previous research findings and review the latest development and clinical influence of poststent optical coherence tomographic findings of coronary artery

参考文献/References:

[1] Im E,Kim BK,Ko YG,et al. Incidences,predictors,and clinical outcomes of acute and late stent malapposition detected by optical coherence tomography after drug-eluting stent implantation[J]. Circ Cardiovasc Interv,2014,7(1):88-96.

[2] Sarno G,Lagerqvist B,Nilsson J,et al. Stent thrombosis in new-generation drug-eluting stents in patients with STEMI undergoing primary PCI:a report from SCAAR[J]. J Am Coll Cardiol,2014,64(1):16-24.

[3] Prati F,Romagnoli E,Burzotta F,et al. Clinical impact of OCT findings during PCI:the CLI-OPCI Ⅱ study [J]. JACC Cardiovasc Imaging,2015,8(11):1297-1305.

[4] Romagnoli E,Gatto L,La Manna A,et al. Role of residual acute stent malapposition in percutaneous coronary interventions[J]. Catheter Cardiovasc Interv,2017,90(4):566-575.

[5] Mintz GS. Why are we so concerned with acute incomplete stent apposition?[J]. Eur Heart J Cardiovasc Imaging,2015,16(1):110-111.

[6] Foin N,Lu S,Ng J,et al. Stent malapposition and the risk of stent thrombosis:mechanistic insights from an in vitro model[J]. EuroIntervention,2017,13(9):e1096-e1098.

[7] Ozaki Y,Okumura M,Ismail TF,et al. The fate of incomplete stent apposition with drug-eluting stents:an optical coherence tomography-based natural history study[J]. Eur Heart J,2010,31(12):1470-1476.

[8] Adriaenssens T,Joner M,Godschalk TC,et al. Optical coherence tomography findings in patients with coronary stent thrombosis:a report of the PRESTIGE consortium (prevention of late stent thrombosis by an interdisciplinary global european effort)[J]. Circulation,2017,136(11):1007-1021.

[9] Prati F,Romagnoli E,La Manna A,et al. Long-term consequences of optical coherence tomography findings during percutaneous coronary intervention:the centro per la lotta contro l’infarto-optimization of percutaneous coronary intervention (CLI-OPCI) LATE study[J]. EuroIntervention,2018,14(4):e443-e451.

[10] Lee SY,Im E,Hong SJ,et al. Severe acute stent malapposition after drug-eluting stent implantation:effects on long-term clinical outcomes[J]. J Am Heart Assoc,2019,8(13):e012800.

[11] Lombardi M,Chiabrando JG,Romagnoli E,et al. Impact of acute and persistent stent malapposition after percutaneous coronary intervention on adverse cardiovascular outcomes[J]. Minerva Cardiol Angiol,2023,71(5):525-534.

[12] Kim BG,Kachel M,Kim JS,et al. Clinical implications of poststent optical coherence tomographic findings:severe malapposition and cardiac events[J]. JACC Cardiovasc Imaging,2022,15(1):126-137.

[13] Ali ZA,Karimi Galougahi K,Shlofmitz RA,et al. The "oculo-appositional reflex":should optical coherence tomography-detected stent malapposition be corrected?[J]. J Am Heart Assoc,2019,8(7):e012262.

[14] Hong SJ,Park KH,Ahn CM,et al. Severe acute stent malapposition follow-up:3-month and 12-month serial quantitative analyses by optical coherence tomography[J]. Int J Cardiol,2020,299:81-86.

[15] R?ber L,Mintz GS,Koskinas KC,et al. Clinical use of intracoronary imaging. Part 1:guidance and optimization of coronary interventions. An expert consensus document of the european association of percutaneous cardiovascular interventions[J]. Eur Heart J,2018,39(35):3281-3300.

[16] Gutiérrez-Chico JL,Wykrzykowska J,Nüesch E,et al. Vascular tissue reaction to acute malapposition in human coronary arteries:sequential assessment with optical coherence tomography[J]. Circ Cardiovasc Interv,2012,5(1):20-9,S1-S8.

[17] 中华医学会心血管病学分会. 冠状动脉生物可吸收支架临床应用中国专家共识[J]. 中华心血管病杂志,2020,48(5):350-358.

[18] Foin N,Gutiérrez-Chico JL,Nakatani S,et al. Incomplete stent apposition causes high shear flow disturbances and delay in neointimal coverage as a function of strut to wall detachment distance: implications for the management of incomplete stent apposition[J]. Circ Cardiovasc Interv,2014,7(2):180-189.

[19] Soeda T,Uemura S,Park SJ,et al. Incidence and clinical significance of poststent optical coherence tomography findings:one-year follow-up study from a multicenter registry[J]. Circulation,2015,132(11):1020-1029.

[20] Sanuki Y,Sonoda S,Muraoka Y,et al. Contribution of poststent irregular protrusion to subsequent in-stent neoatherosclerosis after the second-generation drug-eluting stent implantation[J]. Int Heart J,2018,59(2):307-314.

[21] Bryniarski KL,Tahk SJ,Choi SY,et al. Clinical,angiographic,IVUS,and OCT predictors for irregular protrusion after coronary stenting[J]. EuroIntervention,2017,12(18):e2204-e2211.

[22] Sohn J,Hur SH,Kim IC,et al. A comparison of tissue prolapse with optical coherence tomography and intravascular ultrasound after drug-eluting stent implantation[J]. Int J Cardiovasc Imaging,2015,31(1):21-29.

[23] Sugiyama T,Kimura S,Ohtani H,et al. Relationship between quantities of tissue prolapse after percutaneous coronary intervention and neointimal hyperplasia at follow-up on serial optical coherence tomography examination[J]. Int J Cardiol,2017,241:470-477.

[24] Qiu F,Mintz GS,Witzenbichler B,et al. Prevalence and clinical impact of tissue?protrusion after stent implantation:an ADAPT-DES intravascular ultrasound substudy[J]. JACC Cardiovasc Interv,2016,9(14):1499-1507.

[25] Choi SY,Witzenbichler B,Maehara A,et al. Intravascular ultrasound findings of early stent thrombosis after primary percutaneous intervention in acute myocardial infarction:a Harmonizing Outcomes with Revascularization and Stents in Acute Myocardial Infarction (HORIZONS-AMI) substudy[J]. Circ Cardiovasc Interv,2011,4(3):239-247.

[26] Sakai S,Sato A,Hoshi T,et al. In vivo evaluation of tissue protrusion by using optical coherence tomography and coronary angioscopy immediately after stent implantation[J]. Circ J,2020,84(12):2235-2243.

[27] Kyodo A,Soeda T,Okamura A,et al. Clinical impact of irregular protrusion angle after coronary stenting at culprit lesions with ST-elevation myocardial infarction-an intravascular optical coherence tomography study[J]. Circ Rep,2021,3(8):431-439.

[28] Miura T,Sonoda S,Sanuki Y,et al. Comparison of post-stent irregular protrusion and subsequent neointimal characteristics between second-and third-generation drug-eluting stent implantation[J]. J Cardiol,2020,76(5):464-471.

[29] Yonetsu T,Hoshino M,Lee T,et al. Plaque morphology assessed by optical coherence tomography in the culprit lesions of the first episode of acute myocardial infarction in patients with low low-density lipoprotein cholesterol level[J]. J Cardiol,2020,75(5):485-493.

[30] Hou J,Xing L,Jia H,et al. Comparison of intensive versus moderate lipid-lowering therapy on fibrous cap and atheroma volume of coronary lipid-rich plaque using serial optical coherence tomography and intravascular ultrasound imaging[J]. Am J Cardiol,2016,117(5):800-806.

[31] Kubo T,Shinke T,Okamura T,et al. Optical frequency domain imaging vs. intravascular ultrasound in percutaneous coronary intervention (OPINION trial):one-year angiographic and clinical results[J]. Eur Heart J,2017,38(42):3139-3147.

[32] Otake H,Kubo T,Takahashi H,et al. Optical Frequency domain imaging versus intravascular ultrasound in percutaneous coronary intervention (OPINION trial):results from the OPINION imaging study[J]. JACC Cardiovasc Imaging,2018,11(1):111-123.

[33] 中华医学会心血管病学分会,中华心血管病杂志编辑委员会. 光学相干断层成像技术在冠心病介入诊疗中应用的中国专家共识[J]. 中华心血管病杂志,2023,51(2):109-124.

[34] Ann SH,Lim KH,De Jin C,et al. Multi-modality imaging for stent edge assessment[J]. Heart Vessels,2015,30(2):162-168.

[35] Chamié D,Bezerra HG,Attizzani GF,et al. Incidence,predictors,morphological characteristics,and clinical outcomes of stent edge dissections detected by optical?coherence tomography[J]. JACC Cardiovasc Interv,2013,6(8):800-813.

[36] Bouki KP,Sakkali E,Toutouzas K,et al. Impact of coronary artery stent edge dissections on long-term clinical outcome in patients with acute coronary syndrome:an optical coherence tomography study[J]. Catheter Cardiovasc Interv,2015,86(2):237-246.

[37] Palmerini T,Benedetto U,Biondi-Zoccai G,et al. Long-term safety of drug-eluting and?bare-metal stents:evidence from a comprehensive network meta-analysis[J]. J Am Coll Cardiol,2015,65(23):2496-2507.

[38] Jinnouchi H,Sakakura K,Yanase T,et al. Impact of stent edge dissection detected by optical coherence tomography after current-generation drug-eluting stent implantation[J]. PLoS One,2021,16(11):e0259693.

[39] Stone GW,Rizvi A,Newman W,et al. Everolimus-eluting versus paclitaxel-eluting stents in coronary artery disease[J]. N Engl J Med,2010,362(18):1663-1674.

[40] Kobayashi N,Mintz GS,Witzenbichler B,et al. Prevalence,features,and prognostic importance of edge dissection after drug-eluting stent implantation:an ADAPT-DES intravascular ultrasound substudy[J]. Circ Cardiovasc Interv,2016,9(7):e003553.

[41] Prati F,Romagnoli E,Gatto L,et al. Clinical Impact of suboptimal stenting and residual intrastent plaque/thrombus protrusion in patients with acute coronary syndrome:the CLI-OPCI ACS Substudy (centro per la lotta contro l’infarto-optimization of percutaneous coronary intervention in acute coronary syndrome)[J]. Circ Cardiovasc Interv,2016,9(12):e003726.

[42] Radu MD,R?ber L,Heo J,et al. Natural history of optical coherence tomography-detected non-flow-limiting edge dissections following drug-eluting stent implantation[J]. EuroIntervention,2014,9(9):1085-1094.

[43] Prati F,Romagnoli E,Biccirè FG,et al. Clinical outcomes of suboptimal stent deployment as assessed by optical coherence tomography:long-term results of the CLI-OPCI registry [J]. EuroIntervention,2022,18(2):e150-e157.

[44] Ali ZA,Landmesser U,Maehara A,et al. Optical coherence tomography-guided versus angiography-guided PCI[J]. N Engl J Med,2023,389(16):1466-1476.

[45] van Zandvoort LJC,Tomaniak M,Tovar Forero MN,et al. Predictors for clinical outcome of untreated stent edge dissections as detected by optical coherence tomography[J]. Circ Cardiovasc Interv,2020,13(3):e008685.

相似文献/References:

[1]刘明阳?赵晨?郝伟?贾海波?于波.冠状动脉生物可吸收支架临床应用最新进展[J].心血管病学进展,2023,(7):649.[doi:10.16806/j.cnki.issn.1004-3934.2023.07.017]
 LIU Mingyang,ZHAO Chen,HAO Wei,et al.Clinical Application of Coronary Bioabsorbable Scaffolds[J].Advances in Cardiovascular Diseases,2023,(7):649.[doi:10.16806/j.cnki.issn.1004-3934.2023.07.017]

更新日期/Last Update: 2024-08-09