[1]欧振宏 陈芸霖 殷跃辉.盐水灌注导管在肾去交感神经消融术中的应用[J].心血管病学进展,2021,(7):637-641.[doi:10.16806/j.cnki.issn.1004-3934.2021.07.015]
 OU Zhenhong,CHEN Yunlin,YIN Yuehui.Application of Saline-Irrigated Catheter in?span>Renal Sympathetic Denervation[J].Advances in Cardiovascular Diseases,2021,(7):637-641.[doi:10.16806/j.cnki.issn.1004-3934.2021.07.015]
点击复制

盐水灌注导管在肾去交感神经消融术中的应用()
分享到:

《心血管病学进展》[ISSN:51-1187/R/CN:1004-3934]

卷:
期数:
2021年7期
页码:
637-641
栏目:
出版日期:
2021-07-25

文章信息/Info

Title:
Application of Saline-Irrigated Catheter in?span>Renal Sympathetic Denervation
作者:
欧振宏1 陈芸霖 2 殷跃辉 2
(1.重庆医科大学研究生院,重庆 400010;2.重庆医科大学附属第二医院心血管内科,重庆 400010)
Author(s):
OU Zhenhong1 CHEN Yunlin2 YIN Yuehui12
?1.Chongqing Medical University Graduate School,Chongqing 400010,China; 2.Department of Cardiology,The Second Affiliated Hospital of Chongqing Medical University,Chongqing 400010,China)
关键词:
盐水灌注导管肾去交感神经消融术射频导管消融
Keywords:
Saline-irrigated catheterRenal sympathetic denervationRadiofrequency catheter ablation
DOI:
10.16806/j.cnki.issn.1004-3934.2021.07.015
摘要:
盐水灌注导管通过降低电极组织界面温度,能进一步安全地增加消融深度和产生符合肾动脉周围神经分布的消融损伤。已有研究证实其可安全地应用于肾去交感神经消融术中,实现较非灌注导管相似或更佳的去神经效应。现就盐水灌注导管在肾动脉消融中的应用做一综述。
Abstract:
Saline-irrigated catheter can further increase the depth of lesion more safely and produce the ablation damage in line with the distribution of nerves around the renal artery by reducing electrode tissue interface temperature. Studies have confirmed that saline-irrigated catheter can be safely applied to renal sympathetic denervation and achieved a similar or better effect than non-irrigated catheter. This article reviewed the application of saline -irrigated catheter in renal sympathetic denervation

参考文献/References:

[1]Manolis AJ,Poulimenos LE,Kallistratos MS,et al. Sympathetic overactivity in hypertension and cardiovascular disease[J]. Curr Vasc Pharmacol,2014,12(1):4-15.

[2]Chinushi M,Izumi D,Iijima K,et al. Blood pressure and autonomic responses to electrical stimulation of the renal arterial nerves before and after ablation of the renal artery[J]. Hypertension,2013,61(2):450-456.

[3]Linz D,Hohl M,Elliott AD,et al. Modulation of renal sympathetic innervation:recent insights beyond blood pressure control[J]. Clin Auton Res,2018,28(4):375-384.

[4]Krum H,Schlaich M,Whitbourn R,et al. Catheter-based renal sympathetic denervation for resistant hypertension:a multicentre safety and proof-of-principle cohort study[J]. Lancet,2009,373(9671):1275-1281.

[5]Esler MD,Krum H,Sobotka PA,et al. Renal sympathetic denervation in patients with treatment-resistant hypertension(The Symplicity HTN-2 Trial):a randomised controlled trial[J]. Lancet,2010,376(9756):1903-1909.

[6]Bhatt DL,Kandzari DE,O’Neill WW,et al. A controlled trial of renal denervation for resistant hypertension[J]. N Engl J Med,2014,370(15):1393-1401.

[7]B?hm M,Kario K,Kandzari DE,et al. Efficacy of catheter-based renal denervation in the absence of antihypertensive medications(SPYRAL HTN-OFF MED Pivotal):a multicentre,randomised,sham-controlled trial[J]. Lancet,2020,395(10234):1444-1451.

[8]Sakakura K,Ladich E,Cheng Q,et al. Anatomic assessment of sympathetic peri-arterial renal nerves in man[J]. J Am Coll Cardiol,2014,64(7):635-643.

[9]Vink EE,Goldschmeding R,Vink A,et al. Limited destruction of renal nerves after catheter-based renal denervation:results of a human case study[J]. Nephrol Dial Transplant,2014,29(8):1608-1610.

[10]Mahfoud F,Pipenhagen CA,Boyce Moon L,et al. Comparison of branch and distally focused main renal artery denervation using two different radio-frequency systems in a porcine model [J]. Int J Cardiol,2017,241:373-378.

[11]Fengler K,Rommel KP,Blazek S,et al. A three-arm randomized trial of different renal denervation devices and techniques in patients with resistant hypertension(RADIOSOUND-HTN)[J]. Circulation,2019,139(5):590-600.

[12]Houmsse M,Daoud EG. Biophysics and clinical utility of irrigated-tip radiofrequency catheter ablation[J]. Expert Rev Med Devices,2012,9(1):59-70.

[13]Nakagawa H,Yamanashi WS,Pitha JV,et al. Comparison of in vivo tissue temperature profile and lesion geometry for radiofrequency ablation with a saline-irrigated electrode versus temperature control in a canine thigh muscle preparation[J]. Circulation,1995,91(8):2264-2273.

[14]Yokoyama K,Nakagawa H,Wittkampf FH,et al. Comparison of electrode cooling between internal and open irrigation in radiofrequency ablation lesion depth and incidence of thrombus and steam pop[J]. Circulation,2006,113(1):11-19.

[15]Petersen HH,Chen X,Pietersen A,et al. Tissue temperatures and lesion size during irrigated tip catheter radiofrequency ablation:an in vitro comparison of temperature-controlled irrigated tip ablation,power-controlled irrigated tip ablation,and standard temperature-controlled ablation[J]. Pacing Clin Electrophysiol,2000,23(1):8-17.

[16]Wong WS,VanderBrink BA,Riley RE,et al. Effect of saline irrigation flow rate on temperature profile during cooled radiofrequency ablation[J]. J Interv Card Electrophysiol,2000,4(1):271-326.

[17]Petersen HH,Chen X,Pietersen A,et al. Temperature-controlled irrigated tip radiofrequency catheter ablation:comparison of in vivo and in vitro lesion dimensions for standard catheter and irrigated tip catheter with minimal infusion rate[J]. J Cardiovasc Electrophysiol,1998,9(4):409-414.

[18]Weiss C,Antz M,Eick O,et al. Radiofrequency catheter ablation using cooled electrodes:impact of irrigation flow rate and catheter contact pressure on lesion dimensions[J]. Pacing Clin Electrophysiol,2002,25(4 Pt 1):463-469.

[19]Nakagawa H,Wittkampf FH,Yamanashi WS,et al. Inverse relationship between electrode size and lesion size during radiofrequency ablation with active electrode cooling[J]. Circulation,1998,98(5):458-465.

[20]Blessing E,Esler MD,Francis DP,et al. Cardiac ablation and renal denervation systems have distinct purposes and different technical requirements[J]. JACC Cardiovasc Interv,2013,6(3):314.

[21]Tzafriri AR,Keating JH,Markham PM,et al. Arterial microanatomy determines the success of energy-based renal denervation in controlling hypertension[J]. Sci Transl Med,2015,7(285):285ra65.

[22]Sakakura K,Ladich E,Fuimaono K,et al. Comparison of renal artery,soft tissue,and nerve damage after irrigated versus nonirrigated radiofrequency ablation[J]. Circ Cardiovasc Interv,2015,8(1):e001720.

[23]Templin C,Jaguszewski M,Ghadri JR,et al. Vascular lesions induced by renal nerve ablation as assessed by optical coherence tomography:pre- and post-procedural comparison with the Simplicity catheter system and the EnligHTN multi-electrode renal denervation catheter[J]. Eur Heart J,2013,34(28):2141-2148,2148b.

[24]Wang Z,Chen S,Zhou T,et al. Comparison of saline-irrigated catheter vs. temperature-controlled catheter for renal denervation in a canine model[J]. Am J Hypertens,2015,28(12):1434-1443.

[25]Chen W,Du H,Lu J,et al. Renal artery vasodilation may be an indicator of successful sympathetic nerve damage during renal denervation procedure [J]. Sci Rep,2016,6:37218.

[26]Kiuchi MG,Chen S,Rodrigues Paz LM,et al. Number of ablated spots in the course of renal sympathetic denervation in CKD patients with uncontrolled hypertension:EnligHTN vs. Standard irrigated cardiac ablation catheter[J]. Hipertens Riesgo Vasc,2018,35(2):54-63.

[27]Ahmed H,Neuzil P,Skoda J,et al. Renal sympathetic denervation using an irrigated radiofrequency ablation catheter for the management of drug-resistant hypertension[J]. JACC Cardiovasc Interv,2012,5(7):758-765.

[28]Kiuchi MG,Maia GL,de Queiroz Carreira MA,et al. Effects of renal denervation with a standard irrigated cardiac ablation catheter on blood pressure and renal function in patients with chronic kidney disease and resistant hypertension[J]. Eur Heart J,2013,34(28):2114- 2121.

[29]Yalagudri S,Raju N,Das B,et al. Renal sympathetic denervation using an externally irrigated radiofrequency ablation catheter for treatment of resistant hypertension—Acute safety and short term efficacy[J]. Indian Heart J,2015,67(3):207-213.

[30]Chen W,Ling Z,Du H,et al. The effect of two different renal denervation strategies on blood pressure in resistant hypertension:comparison of full-length versus proximal renal artery ablation[J]. Catheter Cardiovasc Interv,2016,88(5):786-795.

[31]Armaganijan L,Staico R,Moraes A,et al. Renal denervation using an irrigated catheter in patients with resistant hypertension:a promising strategy?[J]. Arq Bras Cardiol,2014,102(4):355-363.

[32]Pokushalov E,Romanov A,Corbucci G,et al. A randomized comparison of pulmonary vein isolation with versus without concomitant renal artery denervation in patients with refractory symptomatic atrial fibrillation and resistant hypertension[J]. J Am Coll Cardiol,2012,60(13):1163-1170.

[33]Steinberg JS,Shabanov V,Ponomarev D,et al. Effect of renal denervation and catheter ablation vs catheter ablation alone on atrial fibrillation recurrence among patients with paroxysmal atrial fibrillation and hypertension:the ERADICATE-AF Randomized Clinical Trial[J]. JAMA,2020,323(3):248-255.

[34]Chen W,Ling Z,Xu Y,et al. Preliminary effects of renal denervation with saline irrigated catheter on cardiac systolic function in patients with heart failure:a Prospective,Randomized,Controlled,Pilot Study[J]. Catheter Cardiovasc Interv,2017,89(4):E153-E161.

[35]Remo BF,Preminger M,Bradfield J,et al. Safety and efficacy of renal denervation as a novel treatment of ventricular tachycardia storm in patients with cardiomyopathy[J]. Heart Rhythm,2014,11(4):541-546.

[36]Kiuchi MG,GR ES,Paz LM,et al. Proof of concept study:renal sympathetic denervation for treatment of polymorphic premature ventricular complexes[J]. J Interv Card Electrophysiol,2016,47(2):221-229.

更新日期/Last Update: 2021-09-10