[1]范建华 刘庆军.高功率短时程射频消融治疗心房颤动的研究进展[J].心血管病学进展,2020,(8):806-808.[doi:10.16806/j.cnki.issn.1004-3934.2020.08.006]
 FAN JIanhuaLIU Qingjun.High Power Short Duration Radiofrequency Ablation for Atrial Fibrillation[J].Advances in Cardiovascular Diseases,2020,(8):806-808.[doi:10.16806/j.cnki.issn.1004-3934.2020.08.006]
点击复制

高功率短时程射频消融治疗心房颤动的研究进展()
分享到:

《心血管病学进展》[ISSN:51-1187/R/CN:1004-3934]

卷:
期数:
2020年8期
页码:
806-808
栏目:
综述
出版日期:
2020-08-25

文章信息/Info

Title:
High Power Short Duration Radiofrequency Ablation for Atrial Fibrillation
作者:
范建华 刘庆军
华 刘庆军 (江苏省南京中医药大学附属昆山中医医院心血管内科,江苏 苏州215300)
Author(s):
FAN JIanhuaLIU Qingjun
(Department of CardiologyTraditional Chinese Medicine Hospital of KunshanAffiliated Nanjing University of Traditional Chinese MedicineSuzhou 215300JiangsuChina)
关键词:
高功率短时程射频消融心房颤动
Keywords:
High power Short duration Radiofrequency ablation Atrial fibrillation
DOI:
10.16806/j.cnki.issn.1004-3934.2020.08.006
摘要:
环肺静脉的电学隔离是心房颤动射频消融的核心,常规射频消融仍然存在耗时较长和过度消融等相关并发症风险。国外研究者采用高功率短时程的射频消融进行环肺静脉隔离,以缩短射频消融的时间,提高肺静脉隔离的效率。现就高功率短时程射频消融的研究进展做一综述。
Abstract:
Electrical isolation of the circumferential pulmonary vein is the core of radiofrequency ablation.Conventional radiofrequency ablation still has the risk of long-time consuming and excessive ablation.Foreign researchers use high power short duration radiofrequency ablation in order to shorten the time of radiofrequency ablation and improve the efficiency of pulmonary vein isolation.This paper reviews the progress of high power short duration radiofrequency ablation

参考文献/References:

[1] 陈佳磊.心房颤动射频导管消融现状[J].心血管病学进展,2018,39(6):893-896.

[2] Winkle RA,Mohanty S,Patrawala RA,et al.Low complication rates using high power (45~50 W) for short duration for atrial fibrillation ablations[J].Heart Rhythm,2019,16(2):165-169.

[3] Raja DC,Sanders P,Pathak RK.How much is enough? An appraisal of high-power short-duration radiofrequency ablation for pulmonary vein isolation[J].J Cardiovasc Electrophysiol,2019,30(11):2205-2208.

[4] Deneke T,Halbfa? P,Pürerfellner H.High-power short duration ablation for pulmonary vein isolation:Simply cranking up the energy[J].Europace,2020,22(3):335-337.

[5] Haines DE.The biophysics of radiofrequency catheter ablation in the heart:the importance of temperature monitoring[J].Pacing Clin Electrophysiol,1993,16(3 Pt 2):586-591.

[6] Hall B,Jeevanantham V,Simon R,et al.Variation in left atrial transmural wall thickness at sites commonly targeted for ablation of atrial fibrillation[J].J Interv Card Electrophysiol,2006,17(2):127-132.

[7] Bhaskaran A,Chik W,Pouliopoulos J,et al.Five seconds of 50~60 W radio frequency atrial ablations were transmural and safe:an in vitro mechanistic assessment and force-controlled in vivo validation[J].Europace,2017,19(5):874-880.

[8] Barkagan M,Contreras-Valdes FM,Leshem E,et al.High-power and short-duration ablation for pulmonary vein isolation:Safety,efficacy,and long-term durability[J].J Cardiovasc Electrophysiol,2018,29(9):1287-1296.

[9] Leshem E,Zilberman I,Tschabrunn CM,et al.High-power and short-duration ablation for pulmonary vein isolation:biophysical?characterization[J].JACC Clin Electrophysiol,2018,4(4):467-479.

[10] Nilsson B,Chen X,Pehrson S,et al.The effectiveness of a high output/short duration radiofrequency current application technique in segmental pulmonary vein isolation for atrial fibrillation[J].Europace,2006,8(11):962-965.

[11] Kottmaier M,Popa M,Bourier F,et al.Safety and outcome of very high-power short-duration ablation using 70 W for pulmonary vein isolation in patients with paroxysmal atrial fibrillation[J].Europace,2020,22(3):388-393.

[12] Reddy VY,Grimaldi M,de Potter T,et al.Pulmonary vein isolation with very?high?power,short duration,temperature-controlled lesions:the QDOT-FAST trial[J].JACC Clin Electrophysiol,2019,5(7):778-786.

[13] Yu W,Hu P,Wang S,et al.Distal radial artery access in the anatomical snuffbox for coronary angiography and intervention:a single center experience [J].Medicine(Baltimore),2020,99(3):e18330.

[14] Barbhaiya CR,Kogan EV,Jankelson L,et al.Esophageal temperature dynamics during high-power short-duration posterior wall ablation[J].Heart Rhythm,2020,17(5 Pt A):721-727.

[15] Baher A,Kheirkhahan M,Rechenmacher SJ,et al.High-power radiofrequency catheter?ablation of atrial fibrillation:using late gadolinium enhancement magnetic resonance imaging as a novel?index?of?esophageal injury[J].JACC Clin Electrophysiol,2018,4(12):1583-1594.

[16] Castrejón-Castrejón S,Martínez Cossiani M,Ortega Molina M,et al.Feasibility and safety of pulmonary vein isolation by high-power short-duration radiofrequency application:short-term results of the POWER-FAST PILOT study[J].J Interv Card Electrophysiol,2020,57(1):57-65.

[17] Bourier F,Duchateau J,Vlachos K,et al.High-power short-duration versus standard radiofrequency ablation:Insights on lesion metrics[J].J Cardiovasc Electrophysiol,2018,29(11):1570-1575.

[18] Kanamori N,Kato T,Sakagami S,et al.Optimal lesion size index to prevent conduction gap during pulmonary vein isolation[J].J Cardiovasc Electrophysiol,2018,29(12):1616-1623.

[19] Okamatsu H,Koyama J,Sakai Y,et al.High-power application is associated with shorter procedure time and higher rate of first-pass pulmonary vein isolation in ablation index-guided atrial fibrillation ablation[J].J Cardiovasc Electrophysiol,2019,30(12):2751-2758.

[20] Barkagan M,Leshem E,Rottmann M,et al.Expandable lattice electrode ablation catheter[J].Circ Arrhythm Electrophysiol,2019,12(4):e007090.

备注/Memo

备注/Memo:

通讯作者:刘庆军,E-mail:dr.liuqingjun@hotmail.com

收稿日期:2020-02-23

更新日期/Last Update: 2020-11-02